Structural Engineer / Draughtsman
4819
$$
- Posted:
- Proposals: 10
- Remote
- #20028
- Archived
Designer in Microstation & AutoCAD; Architectural & Building Construction Design Consultant (Qualified) and Surveyor
Borehamwood
Structural Cad Technician / Structural Design / Cad Technician / Draughtsman / RC Detailer / Measured Surveys / Subsidence Investigation/Precast Concrete Design & Detailer
Midlands
640076538766602430996580966093125140145276148261148598
Description
Experience Level: Intermediate
This is what we need someone to do:
The selected supplier will be expected to develop the structural drawings and details from the general construction drawings and details in AutoCad provided by the Architect together with the structural design specifications provided by the Structural Engineer. The drawings will include all the measurements on plan including cross sections. Our engineer will also provide structural calculations to demonstrate compliance with the Building Regulations Part A.
From these Structural Calculations, the size of the Compression and Tension reinforcement in the concrete beams and columns can be ascertained. The detailer / draughtsman is required to use the BS 8666:2005 Standard Shape Codes to produce on CAD:
· Floor plans Drawings ,
· Cross Sections
· Bending Schedules.
· Steel beams details
· Concrete beams details
· Bearings details
· Piles details
· Ground beams details
· The retaining wall detail.
You will be required to lease with the structural engineer for the calculation of the reinforcement lengths, radius, splice lengths and anchorage lengths from BS 8666:2000.
You can view the plans by using this link:
<http://dl.dropbox.com/u/5970743/061_100318_Building%20Control.zip>
The selected supplier will be expected to develop the structural drawings and details from the general construction drawings and details in AutoCad provided by the Architect together with the structural design specifications provided by the Structural Engineer. The drawings will include all the measurements on plan including cross sections. Our engineer will also provide structural calculations to demonstrate compliance with the Building Regulations Part A.
From these Structural Calculations, the size of the Compression and Tension reinforcement in the concrete beams and columns can be ascertained. The detailer / draughtsman is required to use the BS 8666:2005 Standard Shape Codes to produce on CAD:
· Floor plans Drawings ,
· Cross Sections
· Bending Schedules.
· Steel beams details
· Concrete beams details
· Bearings details
· Piles details
· Ground beams details
· The retaining wall detail.
You will be required to lease with the structural engineer for the calculation of the reinforcement lengths, radius, splice lengths and anchorage lengths from BS 8666:2000.
You can view the plans by using this link:
<http://dl.dropbox.com/u/5970743/061_100318_Building%20Control.zip>
JL Homes L.
0% (0)Projects Completed
1
Freelancers worked with
1
Projects awarded
0%
Last project
28 May 2013
United Kingdom
New Proposal
Login to your account and send a proposal now to get this project.
Log inClarification Board Ask a Question
-
There are no clarification messages.
We collect cookies to enable the proper functioning and security of our website, and to enhance your experience. By clicking on 'Accept All Cookies', you consent to the use of these cookies. You can change your 'Cookies Settings' at any time. For more information, please read ourCookie Policy
Cookie Settings
Accept All Cookies