Code programming for CC2650 MODA
- or -
Post a project like this$$
- Posted:
- Proposals: 0
- Remote
- #1382833
- Expired
Description
Experience Level: Intermediate
Hello
I just need programming for the product of the following link.
http://www.ti.com/lit/ds/swrs187a/swrs187a.pdf
I have the hardware desing with another anthena, with another coleagues I need a programming example.
The idea is measure 2 ADC make the diference between both (in case that the chip has referenced ADC just need to read one adc input) that operation make 10 times or 16 times for a average, an output wich will be enabled during the measured period then trasmmit the value to the other anthena and go to the lowest cosume state up to 10 mSec, the other side recieve the information measured and it is trammited via SPI.
The main idea is a well explained program and a consumption study with excel sheet.
this is the maesure concept
Output Disabled trasmitting then go to lowest consumption state
Output enabled , wait 400 micro seconds; start measuring 1adc conversion....2 ....3 up to 10 adc conversion make the average (chose 10 or 16 as you wish for faster divide operation), then trasmmit and go to lowest consumption state, on the other side receieve the information and decode then send it trough SPI.
The consumption is required on the first side.
Thanks in advance.
I just need programming for the product of the following link.
http://www.ti.com/lit/ds/swrs187a/swrs187a.pdf
I have the hardware desing with another anthena, with another coleagues I need a programming example.
The idea is measure 2 ADC make the diference between both (in case that the chip has referenced ADC just need to read one adc input) that operation make 10 times or 16 times for a average, an output wich will be enabled during the measured period then trasmmit the value to the other anthena and go to the lowest cosume state up to 10 mSec, the other side recieve the information measured and it is trammited via SPI.
The main idea is a well explained program and a consumption study with excel sheet.
this is the maesure concept
Output Disabled trasmitting then go to lowest consumption state
Output enabled , wait 400 micro seconds; start measuring 1adc conversion....2 ....3 up to 10 adc conversion make the average (chose 10 or 16 as you wish for faster divide operation), then trasmmit and go to lowest consumption state, on the other side receieve the information and decode then send it trough SPI.
The consumption is required on the first side.
Thanks in advance.
Emanuel L.
100% (2)Projects Completed
3
Freelancers worked with
3
Projects awarded
8%
Last project
11 Dec 2017
Argentina
New Proposal
Login to your account and send a proposal now to get this project.
Log inClarification Board Ask a Question
-
There are no clarification messages.
We collect cookies to enable the proper functioning and security of our website, and to enhance your experience. By clicking on 'Accept All Cookies', you consent to the use of these cookies. You can change your 'Cookies Settings' at any time. For more information, please read ourCookie Policy
Cookie Settings
Accept All Cookies