Structural Design for Bungalow with basement
- or -
Post a project like this$$
- Posted:
- Proposals: 6
- Remote
- #1776411
- Expired
Description
Experience Level: Intermediate
Hello I do hope you can help.
I am about to start on a self build project, and have started getting quotations, but am being asked for structural drawings in order to get accurate quotes. I hope you can help
The plans have been approved, with the exception of the basement, which I may or may not be able to afford or get planning for, but I would like to have a idea of build costs
I would like structural drawings for the single storey house including basement, as soon as is possible I would like to know the feasibility of building the basement walls, using either
1) Durisol Blocks 375mm, reinforced with rebars and filled with concrete OR
2) 440 x 215m Hollow Cinder Blocks, with rebars and filled with concrete
I am hoping to build the main building using SIPs or MGO Sips and have no internal columns and as few as possible externals columns, please see attached drawing.
I am hoping that I would be able to use steel beams that are no higher than 203mm, as the agreed plan allows for an external height 2.7m (as attached) an I would need to do a warm roof with at lease 200mm of insulation, which leaves me with a internal roof height of 2.3m, while I am hoping for at least 2.4
Please let me know if you are able to help
I am about to start on a self build project, and have started getting quotations, but am being asked for structural drawings in order to get accurate quotes. I hope you can help
The plans have been approved, with the exception of the basement, which I may or may not be able to afford or get planning for, but I would like to have a idea of build costs
I would like structural drawings for the single storey house including basement, as soon as is possible I would like to know the feasibility of building the basement walls, using either
1) Durisol Blocks 375mm, reinforced with rebars and filled with concrete OR
2) 440 x 215m Hollow Cinder Blocks, with rebars and filled with concrete
I am hoping to build the main building using SIPs or MGO Sips and have no internal columns and as few as possible externals columns, please see attached drawing.
I am hoping that I would be able to use steel beams that are no higher than 203mm, as the agreed plan allows for an external height 2.7m (as attached) an I would need to do a warm roof with at lease 200mm of insulation, which leaves me with a internal roof height of 2.3m, while I am hoping for at least 2.4
Please let me know if you are able to help
Beresford G.
0% (0)Projects Completed
-
Freelancers worked with
-
Projects awarded
0%
Last project
7 May 2024
United Kingdom
New Proposal
Login to your account and send a proposal now to get this project.
Log inClarification Board Ask a Question
-
Hi
I need a site visit to check everything then design structure and provide drawing for you. site visit depend on site location has different cost. -
Is it possible for you to provide additional details about your structure?