Experience Level: Entry
I am seeking a quotation for the amendment and reissue of an existing drainage layout drawing relating to a planning condition discharge submission for a mixed-use conversion project at:
95 High Street
Chelmsford
CM1 1DX
Background
A drainage layout drawing has already been prepared and submitted to the drainage officer (Essex County Council / LLFA).
Following review, the drainage officer has requested a small number of amendments before the drainage strategy can be accepted.
The drainage principle itself has already been agreed and no redesign is required.
Scope Required
I require the existing drainage layout drawing to be amended and reissued in PDF format incorporating the following:
• Clearly show separate foul and surface water systems throughout
• Clearly show foul drainage discharging to the public foul sewer (FW)
• Clearly show surface water drainage discharging to the public surface water sewer (SW)
• Remove any implication that foul and surface water connect into a combined lateral drain before reaching the public network
• Add annotation confirming surface water discharge will be restricted to 2.0 litres per second
• Update notes and key accordingly
• Retain existing architectural floor plans and existing drainage routes where possible
Information Available
I can provide:
• Existing drainage layout drawing (PDF)
• Approved floor plans
• Drainage officer comments
• Mark-up instructions
• Site photographs and location information if required
Deliverables
• Revised drainage layout drawing (PDF)
• Submission-ready version suitable for issue to Essex County Council drainage officer
95 High Street
Chelmsford
CM1 1DX
Background
A drainage layout drawing has already been prepared and submitted to the drainage officer (Essex County Council / LLFA).
Following review, the drainage officer has requested a small number of amendments before the drainage strategy can be accepted.
The drainage principle itself has already been agreed and no redesign is required.
Scope Required
I require the existing drainage layout drawing to be amended and reissued in PDF format incorporating the following:
• Clearly show separate foul and surface water systems throughout
• Clearly show foul drainage discharging to the public foul sewer (FW)
• Clearly show surface water drainage discharging to the public surface water sewer (SW)
• Remove any implication that foul and surface water connect into a combined lateral drain before reaching the public network
• Add annotation confirming surface water discharge will be restricted to 2.0 litres per second
• Update notes and key accordingly
• Retain existing architectural floor plans and existing drainage routes where possible
Information Available
I can provide:
• Existing drainage layout drawing (PDF)
• Approved floor plans
• Drainage officer comments
• Mark-up instructions
• Site photographs and location information if required
Deliverables
• Revised drainage layout drawing (PDF)
• Submission-ready version suitable for issue to Essex County Council drainage officer
Noah C.
0% (0)Projects Completed
-
Freelancers worked with
-
Projects awarded
0%
Last project
3 Jun 2026
United Kingdom
New Proposal
Login to your account and send a proposal now to get this project.
Log inClarification Board Ask a Question
-

Hi Noah, do you have the drainage layout in CAD format?