Cladding Panel Cutting List + Connection Detail Drawings
- or -
Post a project like this£150(approx. $202)
- Posted:
- Proposals: 6
- Remote
- #4387194
- OPPORTUNITY
- Expired
Structural Engineer, CAD designer, interior/ exterior designer, SketchUp, SolidWorks, CAD/CAM, Mechanical Engineer, DS CATIA, 3D Rendering, 3D Model, Surface modeling

Lighting | DIALux I Electrical I MEP |MATLAB I Solar|PCB I Firmware |Embedded
118443497019008120950917569535119017915826915





Description
Experience Level: Expert
We are developing a new warehouse facility in the UK and require a qualified draughtsman / construction engineer / architectural technician with experience in insulated wall and roof cladding (EPS/PIR) to carry out detailed work based on our steel frame structure.
You will be provided with:
• A 3D IFC file of the full steel frame structure
• Panel types (EPS/PIR) and thicknesses
• Total m² for roof and wall panels
• Supplier requirements and shipping restrictions (max 11.9m panel length for 40HC containers)
What we need from you:
✅ Deliverables:
• Cladding Cutting List
• Calculate and list the required panel lengths after splitting oversized panels to meet shipping container limits.
• Include overlap allowances and how many pieces of each length are needed for:
• Roof panels (original length 14.7–15m)
• Wall panels (height ~8–9m)
• Output: Excel or tabulated format showing length, type, and quantity.
• Connection Detail Drawings
• Provide clear cladding connection drawings to show how panels will be fixed to the steel structure.
• Indicate fastening details, overlaps, edge connections, and any support brackets if needed.
• Flashing & Trimming Drawings
• Based on the structure, create drawings with bending angles and dimensions for any flashing or trimming accessories.
• Ensure fabrication-ready precision (drawings should suit Chinese manufacturing standards).
You will be provided with:
• A 3D IFC file of the full steel frame structure
• Panel types (EPS/PIR) and thicknesses
• Total m² for roof and wall panels
• Supplier requirements and shipping restrictions (max 11.9m panel length for 40HC containers)
What we need from you:
✅ Deliverables:
• Cladding Cutting List
• Calculate and list the required panel lengths after splitting oversized panels to meet shipping container limits.
• Include overlap allowances and how many pieces of each length are needed for:
• Roof panels (original length 14.7–15m)
• Wall panels (height ~8–9m)
• Output: Excel or tabulated format showing length, type, and quantity.
• Connection Detail Drawings
• Provide clear cladding connection drawings to show how panels will be fixed to the steel structure.
• Indicate fastening details, overlaps, edge connections, and any support brackets if needed.
• Flashing & Trimming Drawings
• Based on the structure, create drawings with bending angles and dimensions for any flashing or trimming accessories.
• Ensure fabrication-ready precision (drawings should suit Chinese manufacturing standards).

Zain S.
0% (0)Projects Completed
-
Freelancers worked with
-
Projects awarded
0%
Last project
26 Jul 2025
United Kingdom
New Proposal
Login to your account and send a proposal now to get this project.
Log inClarification Board Ask a Question
-
There are no clarification messages.
We collect cookies to enable the proper functioning and security of our website, and to enhance your experience. By clicking on 'Accept All Cookies', you consent to the use of these cookies. You can change your 'Cookies Settings' at any time. For more information, please read ourCookie Policy
Cookie Settings
Accept All Cookies