Basic 2D CAD Drafter for Floor Plan Digitization.
- or -
Post a project like this28
£40(approx. $54)
- Posted:
- Proposals: 23
- Remote
- #4524275
- Awarded
Website Designer & Developer | WordPress ,Woocoomerce & Wix Expert| Mobile App Developer |Full-Stack Developer | SEO Specialist | Shopify Expert

Architect|CAD Designer|3D visualizer|Civil Engineer|structure engineer|logo design|quantity surveying|CNC G-Code programming|laser cutting machine
1287867013421655112408109357298126805811074996626899613020551196387310927530507536012574417
Description
Experience Level: Entry
Project Overview:
I am a commercial landlord requiring a skilled CAD drafter to convert my sketches and dimensions into clean 2D floor plans. No architectural/compliance consultancy is required. I have already determined the fire strategy. Your job is strictly to draw the plans to scale and apply my exact text annotations so I can submit the PDF to Building Control.
General Note to Apply to All Plans:
• "Unit separation walls to achieve 60-minute fire resistance via EITHER minimum 100mm solid dense blockwork OR upgraded timber stud partition (clad both sides with 2x 12.5mm fire-rated plasterboard, joints staggered and taped). Final construction method to be determined on site."
Scope 1: First Floor Shell (~2,500 sq ft)
• Dimensions: 94.7ft x 92.3ft. Pinch point width: 21.5ft. Built-in toilet block (13ft x 11ft) on right side against the 94.7ft wall, ending 70ft from the far partition.
• Annotations to add:
o Lift Staircase (Main Entrance): "Staircase open to first-floor compartment (health & safety barrier only). Full 60-minute fire separation and FD60S door provided at ground-floor level."
o Cornfield St Staircase (Secondary Exit): "Active secondary escape route. Certified FD60S door set, min 850mm clear width, fitted with panic push-bar hardware. Existing plasterboard ceiling over stairwell retained."
o Travel Distance (draw dotted line to both exits): "Maximum Travel Distance to Final Exits: < 45 meters (two independent directions of escape)."
o Ceilings/Voids: "Internal space leased as a shell. All high-level ceilings and tenant enclosures subject to future tenant Building Control application."
Scope 2: Basement Warehouse (~9,000 sq ft)
• Layout: Refer to attached "Basement_Layout.jpg" for the 4 units (1200, 2000, 2200, 4000 sq ft) and central corridor.
• Annotations to add:
o Unit Boundaries & New Fire Corridor: "Existing non-compliant timber demolished. Replaced with full-height 60-minute fire-resisting partitions."
o Toilet Walls: "Existing timber stud upgraded to 60-minute fire resistance via overlaid 12.5mm fire-rated plasterboard."
o Unit Entrances (2.5m wide): "Industrial FD60S double steel doors held open by electromagnetic catches linked to smoke detectors."
o Fire Corridor Exits (2000 & 2200 sq ft units): "Emergency pedestrian exits. Certified FD60S single doors, outward opening, panic hardware."
o Travel Distance (draw dotted line to Fire Corridor): "Max Travel Distance to Protected Corridor: 60 min). Opposite timber s
I am a commercial landlord requiring a skilled CAD drafter to convert my sketches and dimensions into clean 2D floor plans. No architectural/compliance consultancy is required. I have already determined the fire strategy. Your job is strictly to draw the plans to scale and apply my exact text annotations so I can submit the PDF to Building Control.
General Note to Apply to All Plans:
• "Unit separation walls to achieve 60-minute fire resistance via EITHER minimum 100mm solid dense blockwork OR upgraded timber stud partition (clad both sides with 2x 12.5mm fire-rated plasterboard, joints staggered and taped). Final construction method to be determined on site."
Scope 1: First Floor Shell (~2,500 sq ft)
• Dimensions: 94.7ft x 92.3ft. Pinch point width: 21.5ft. Built-in toilet block (13ft x 11ft) on right side against the 94.7ft wall, ending 70ft from the far partition.
• Annotations to add:
o Lift Staircase (Main Entrance): "Staircase open to first-floor compartment (health & safety barrier only). Full 60-minute fire separation and FD60S door provided at ground-floor level."
o Cornfield St Staircase (Secondary Exit): "Active secondary escape route. Certified FD60S door set, min 850mm clear width, fitted with panic push-bar hardware. Existing plasterboard ceiling over stairwell retained."
o Travel Distance (draw dotted line to both exits): "Maximum Travel Distance to Final Exits: < 45 meters (two independent directions of escape)."
o Ceilings/Voids: "Internal space leased as a shell. All high-level ceilings and tenant enclosures subject to future tenant Building Control application."
Scope 2: Basement Warehouse (~9,000 sq ft)
• Layout: Refer to attached "Basement_Layout.jpg" for the 4 units (1200, 2000, 2200, 4000 sq ft) and central corridor.
• Annotations to add:
o Unit Boundaries & New Fire Corridor: "Existing non-compliant timber demolished. Replaced with full-height 60-minute fire-resisting partitions."
o Toilet Walls: "Existing timber stud upgraded to 60-minute fire resistance via overlaid 12.5mm fire-rated plasterboard."
o Unit Entrances (2.5m wide): "Industrial FD60S double steel doors held open by electromagnetic catches linked to smoke detectors."
o Fire Corridor Exits (2000 & 2200 sq ft units): "Emergency pedestrian exits. Certified FD60S single doors, outward opening, panic hardware."
o Travel Distance (draw dotted line to Fire Corridor): "Max Travel Distance to Protected Corridor: 60 min). Opposite timber s
Asmat A.
100% (22)Projects Completed
27
Freelancers worked with
24
Projects awarded
50%
Last project
20 Jun 2026
United Kingdom
New Proposal
Login to your account and send a proposal now to get this project.
Log inClarification Board Ask a Question
-
There are no clarification messages.
We collect cookies to enable the proper functioning and security of our website, and to enhance your experience. By clicking on 'Accept All Cookies', you consent to the use of these cookies. You can change your 'Cookies Settings' at any time. For more information, please read ourCookie Policy