Checking of Structural Calculations and drawings
- or -
Post a project like this2340
£70(approx. $94)
- Posted:
- Proposals: 11
- Remote
- #2284589
- Awarded
2211602234405773578923639591881624256928324977641854724148797325054582435844





Description
Experience Level: Intermediate
Structural Engineer needed!
I have had some structural calculations completed and require someone to completed by a freelancer and require someone to provide a second opinion and check them as there seems to have been a misinterpretation of the requirements.
The calculations are for a single storey kitchen extension project. We need to knock through the external wall and another supporting wall and put some Timber structural beams in.
The freelancer has produced drawings with floor joists in the extension however i have spotted some issues
- it is only single storey extension and for some reason they have placed floor joists in there
- there is a gap where there should be floor joists from the upper floor
- it is not clear if the beams require a lintel or not.
I would also like to understand the implications of running the beam across the whole length of the building (5.59m) as we have an option to move the drain
I have had some structural calculations completed and require someone to completed by a freelancer and require someone to provide a second opinion and check them as there seems to have been a misinterpretation of the requirements.
The calculations are for a single storey kitchen extension project. We need to knock through the external wall and another supporting wall and put some Timber structural beams in.
The freelancer has produced drawings with floor joists in the extension however i have spotted some issues
- it is only single storey extension and for some reason they have placed floor joists in there
- there is a gap where there should be floor joists from the upper floor
- it is not clear if the beams require a lintel or not.
I would also like to understand the implications of running the beam across the whole length of the building (5.59m) as we have an option to move the drain

Patrick H.
100% (15)Projects Completed
13
Freelancers worked with
9
Projects awarded
46%
Last project
28 Mar 2025
United Kingdom
New Proposal
Login to your account and send a proposal now to get this project.
Log inClarification Board Ask a Question
-
Is the building with flat roof, and does that explain the use of floor joists if it could be deemed floor for either escape purposes or if someone was to change it to a balcony.
Without seeing the drawings/calcs would not be able to assess. Any chance of posting the information we are pricing to review ?